Skip to main content

Building Regulations · Approved Document Q

Exceeding PAS 24 as standard

PAS 24 Compliance and BS EN 1627 RC4 Security Specification. Approved Document Q

Every SteelR entrance door is certified beyond the PAS 24 threshold mandated by UK Building Regulations, meeting both Approved Document Q and the fire safety requirements of the Fire Safety Act 2021. Our BS EN 1627:2011 RC4 single leaf, unglazed classification and FD30S fire rating deliver a level of protection that far exceeds the regulatory minimum.

Security Standard Comparison

From building regulations to commercial-grade

Building Regulations Minimum

PAS 24

Document Q Compliant

  • Resists opportunist forced entry
  • Multi-point locking required
  • Laminated glazing if present
  • Required for all new-build dwellings and flats
  • Tested to 15-minute manual attack

SteelR Standard

BS EN 1627 RC4

Single leaf, unglazed · FD30S

  • Resists sustained forced-entry attack with heavy-duty hand tools and battery-operated power tools
  • Tested under BS EN 1627:2011, the European framework for forced-entry resistance
  • Fitted on every residential steel front door we make
  • FD30S fire rated. 30-minute fire and smoke resistance
  • Intumescent seals and cold smoke brushes as standard
  • Satisfies Approved Document Q, Part B and the Fire Safety Act 2021
  • Secured by Design police-preferred specification

Available on Enquiry

LPS 1673

LPCB attack-resistance · Beyond forced-entry

  • Separate LPCB scheme testing resistance to a sustained, directed attack on the asset behind the door
  • Different threat model from BS EN 1627: the protected asset is the target, not opportunist forced entry
  • Four ratings: AR.A300, AR.B180E, AR.B300E, AR.C120E (with E denoting power-tool inclusion)
  • Used on bank vault outer doors, data centre internal cores and embassy residences
  • Available on residential specification by enquiry where a documented threat assessment justifies it
  • Lead time confirmed at quote stage. Pricing individual to the project

The Four-Tier Residential Security Ladder

Standard, Enhanced, Commercial-grade, Ultra-high. Side by side.

BS EN 1627 (RC1 to RC6) and LPS 1175 (SR1 to SR8) are parallel certification schemes operating under different methodologies. They are not interchangeable. The LPCB has stated that over 90% of products tested under EN 1627 RC4 fail to achieve LPS 1175 SR2. SteelR ships RC4 as the standard residential specification on every door, with the LPCB-operated SR3, SR4 and LPS 1673 ratings as named upgrade tiers. The four tiers are not substitutes; they are layered options selected to match the brief.

Four-tier residential security ladder comparison: BS EN 1627 RC4 Standard, LPS 1175 SR3 Enhanced upgrade, LPS 1175 SR4 Commercial-grade upgrade, and LPS 1673 Ultra-high attack-resistance certification.
AttributeTier 1. StandardTier 2. EnhancedTier 3. Commercial-gradeTier 4. Ultra-high
CertificationBS EN 1627:2011 RC4LPS 1175 SR3 (Issue 8)LPS 1175 SR4, D10 Issue 8LPS 1673 attack-resistance
Test schemeEuropean framework. Single leaf, unglazed methodology. UKAS-accredited laboratory.LPCB scheme operated by BRE Global. Police-preferred specification.LPCB Commercial-grade certification under LPS 1175 Issue 8.Separate LPCB attack-resistance scheme. Asset-directed assault, distinct from forced entry.
Attack durationSustained forced-entry test against the complete door assembly.Five-minute sustained attack under the LPS 1175 Issue 8 duration matrix.Longer attack window than SR3 under the same Issue 8 framework.Class-defined: AR.A300, AR.B180E, AR.B300E, AR.C120E. E denotes power-tool inclusion.
Tool catalogueHeavy-duty hand tools and battery-operated power tools.Issue 8 power-tool catalogue. Larger crowbar, higher-energy attack.Issue 8 catalogue plus battery cutting tools and larger prying equipment.Defined by AR class. The threat model is the protected asset behind the door.
Typical specification contextEvery SteelR residential front door. The standard build.High-value properties, conservation areas, listed buildings, insurer-specified or LPCB-preferred briefs.Documented threat assessment, specialist private-bank clients, security-sensitive professions, layered safe-room specs.Bank vault outer doors, data centre internal cores, embassy residences, residential where a documented threat assessment justifies it.
Lead time impactStandard SteelR lead time: 8 to 12 weeks from sign-off to fitted installation.Standard SteelR lead time, 8 to 12 weeks. Confirmed at design sign-off.Standard plus 2 to 3 weeks. Approximately 10 to 14 weeks total.Lead time confirmed at quote stage. Pricing individual to the project.

Every SteelR door also carries PAS 24:2022 certification, FD30S fire and smoke rating, Secured by Design police accreditation, ISO 9001 and ISO 14001 manufacturing, and Made in Britain certification. The four tiers above sit on top of that baseline; they do not replace it.

Reminder: BS EN 1627 RC ratings and LPS 1175 SR ratings are parallel certification schemes, not interchangeable. A door rated to one is not automatically equivalent to a numerically similar rating in the other.

PAS 24:2022

Security Standard

BS EN 1627 RC4

Single leaf, unglazed

FD30S

Fire & Smoke Rated

Secured by Design

Police Preferred Spec

ISO 9001

Certified Manufacturer

LPS 1673

Attack-Resistant on Enquiry

Why new builds and flats require PAS 24, and why BS EN 1627 RC4 is what specifiers choose

Under Approved Document Q of the Building Regulations, all new-build homes and flats, including those created by material change of use, must be fitted with entrance doors that resist unauthorised access. PAS 24:2022 is the accepted standard to satisfy this requirement.

The Fire Safety Act 2021 further extended the Fire Safety Order to explicitly cover flat entrance doors in multi-occupied residential buildings. FD30S fire-rated doorsets are now the mandated minimum standard for any flat entrance door leading onto common parts.

Every SteelR door satisfies both requirements and exceeds both. BS EN 1627:2011 RC4 single leaf, unglazed certification means your door has been independently tested to withstand sustained forced entry with heavy-duty hand tools and battery-operated power tools, not just opportunist attack. It is the standard demanded by housing associations, developers and planning authorities on high-specification projects.

What your SteelR door satisfies

Approved Document Q

Security for dwellings. Mandatory for all new-build houses and flats in England and Wales.

Approved Document B (Part B)

Fire safety. FD30S rating provides 30 minutes fire resistance and cold smoke control.

Fire Safety Act 2021

Flat entrance doors in multi-occupied buildings confirmed within scope. Responsible persons bear legal liability.

Fire Safety (England) Regulations 2022

Annual inspection duties for flat entrance doors in buildings over 11m. SteelR doors are designed for longevity and ongoing compliance.

Building Safety Act 2022

Higher-risk buildings regime. SteelR’s BS EN 1627 RC4 + FD30S certification satisfies the gateway process requirements for higher-risk residential buildings.

Secured by Design. Police Preferred Specification

The UK police initiative accrediting doors to the highest independently verified security standard.

Independently tested performance

Beyond the certifications. The performance numbers behind a SteelR door

Thermal performance

From 1.5 W/m²K standard

BS EN ISO 10077-1, UKAS-accredited test. Thermal-upgrade specifications available achieving as low as 0.8 W/m²K.

Acoustic performance

Up to 39 dB Rw single, 37 dB double

BRE Acoustics test, UKAS-accredited. Critical for London townhouses, urban developments, hotel and apartment projects.

Wind resistance

Class A3 to BS EN 12211 at 1200 Pa

Equivalent to 98 mph sustained wind load. Marine-grade powder-coat finish available for installations within 5 km of the coast.

Air permeability

Class 4 (highest residential class)

BS EN 1026 at 600 Pa (113 km/h equivalent). Ends draught complaints across period properties.

Water tightness

150 Pa outward / 100 Pa inward

BS EN 1027 tested. Built for UK weather with full perimeter compression sealing.

Quality management

ISO 9001 + ISO 14001

Manufactured under both quality and environmental management systems certified by a UKAS-accredited certification body. Made in Britain certified member.

Door leaf construction

44mm to 70mm thick, 1.5mm to 2mm steel skins

Mechanically interlocked and bonded. Mineral-wool insulated core for fire integrity. Steel frame profile from 80mm × 40mm with 25mm reinforcement.

Doorset sizes

Up to 4.804m wide × 3.792m high

Including integrated sidepanels, fanlights and overpanels. Single-leaf, double-leaf or panic-exit configurations.

Environmental Product Declaration

Third-party verified EPD available on request

ISO 14025 framework. BREEAM Mat 01 (Life-cycle impacts) and Mat 03 (Responsible sourcing) credit-eligible. Architects and specifiers download on enquiry.

Specify with confidence

Request a compliance specification sheet or discuss your project